Page 216 of 378 Install and configure ITG ISL Trunk node
553-3001-202 Standard 1.00 April 2000
Setting the Leader 0 IP address

Configure the IP address of the Leader 0 ITG card, using the ITG shell

command line inte rface.

1To access the ITG shell, connect a MAT PC to the RS232 serial
maintenance port on the faceplate of the ITG Lead er 0 car d through an
NTAG81CA PC Maintenance cable. If required, use an NTAG81BA
Maintenance Extender cable to provide an extension between the
NTAG81CA PC Maintenance cable and the MAT PC.
Alternatively, connect the NTAG81BA Maintenanc e Ext ender cab le to
the female DB - 9 connector of the NTCW84KA Management Port,
DCH, and Serial I/O cable for DCHIP cards, or the NTMF94EA E-LAN,
T-LAN, RS232 Ports cable for non-DCHIP cards, to create a more
permanent connection to the ITG Trunk card serial maintenance port.
Note:
Never connect two terminals to the faceplate and I/O panel
breakout cable serial maintenance port connectors at the same time.
2Use the following communication parameters for the TTY terminal
emulation on the MAT ITG PC: 9600 baud, 8 bits, no parity bit, one
stop bit.
When a new ITG Trunk card starts up and displays "T:20" on the
4-character display, the ITG card will begin sending boot p requests on
the E-LAN. A series of dots appears on the TTY.
3Type +++ to bring up the ITG shell command line prompt:
...+++
When prompted to login, enter the def ault use rname and password as:
VxWorks login: itgadmin
Password: itgadmin
ITG>