Chapter 7 Servo ParametersASDA-AB Series

Gain and Switch

 

 

 

 

 

 

 

Control

 

Related

 

 

Parameter

Name

Function

Default

Unit

 

Mode

 

Section of

 

 

 

 

 

 

 

User

 

 

 

 

 

 

 

Pt

Pr

S

T

 

 

 

 

 

 

 

 

 

Manual

 

 

P2-00

KPP

Proportional Position Loop Gain

35

rad/s

{

{

 

 

 

6.2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-01

PPR

Position Loop Gain Switching Rate

100

%

{

{

 

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-02

PFG

Position Feed Forward Gain

5000

0.0001

{

{

 

 

 

6.2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-03

PFF

Smooth Constant of Position Feed

5

ms

{

{

 

 

 

---

 

 

Forward Gain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-04

KVP

Proportional Speed Loop Gain

500

rad/s

{

{

{

{

 

6.3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-05

SPR

Speed Loop Gain Switching Rate

100

%

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-06

KVI

Speed Integral Compensation

100

N/A

{

{

{

{

 

6.3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-07

SFG

Speed Feed Forward Gain

0

0.0001

 

{

{

{

 

6.3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-26

DST

External Anti-Interference Gain

0

0.001

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-27

GCC

Gain Switching Control Selection

0

N/A

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-28

GUT

Gain Switching Time Constant

10

10ms

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pulse

 

 

 

 

 

 

 

 

P2-29

GPE

Gain Switching Condition

10000

Kpps

{

{

{

{

 

---

 

 

 

 

 

 

r/min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-31■

AUT1

Auto Mode Responsiveness Level

44

N/A

{

{

{

{

 

6.3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2-32▲

AUT2

Tuning Mode Selection

0

N/A

{

{

{

{

 

6.3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation of symbols (marked after parameter)

()

Read-only register.

(▲)

Parameter cannot be set when Servo On (when the servo drive is enabled).

(●)

Parameter is effective only after the servo drive is restarted (after switching power off and on).

(■)

Parameter setting values are not retained when power is off.

Revision March 2008, Doc. Name: 2007PDD23000011