P2 - 25

 

 

Chapter 7 Servo ParametersASDA-AB Series

 

 

 

 

 

NLP

Low-pass Filter Time Constant

 

Communication Addr.: 0219H

 

(Resonance Suppression)

 

 

 

 

 

 

Default: 2

(1kW and below models) or

 

Related Section:

 

5

(above 1kW models)

 

Section 6.3.7

Applicable Control Mode: ALL

Unit: ms

Range: 0 ~ 1000

Settings: 0: Disabled

This parameter is used to set low-pass filter time constant of resonance suppression.

P2 - 26

DST

External Anti-Interference Gain

Communication Addr.: 021AH

 

 

 

Default: 0

 

Related Section: N/A

Applicable Control Mode: ALL

Unit: 0.001

Range: 0 ~ 30000

Settings: 0: Disabled

In AutoMode (PDFF) mode (parameter P2-32 is set to 4 or 5), the value of this parameter is determined by the system automatically.

P2 - 27

GCC

Gain Switching Control Selection

Communication Addr.: 021BH

 

 

 

Default: 0

 

Related Section: N/A

Applicable Control Mode: ALL

Unit: N/A

Range: 0 ~ 4

Settings:

Gain Switching Condition Settings:

0:Disabled

1:Gain switching DI signal (GAINUP) is On. (see Table 7.A)

2:In position mode, position deviation is higher than the setting value of P2-29.

3:Position command frequency is higher than the setting value of P2-29.

4:Servo motor speed is higher than the setting value of P2-29.

Revision March 2008, Doc. Name: 2007PDD23000011

7-59