Chapter 12 Application ExamplesASDA-AB Series

When the setting value of the time listed below is set to zero(0), the relative position will be ignored.

Positioning Point

Position Command Register

Moving Speed Register

Dwell Time Register

INDEX1

( P1-15, P1-16 )

P2-36 (V1)

P2-52 (T1)

 

 

 

 

INDEX2

( P1-17, P1-18 )

P2-37 (V2)

P2-53 (T2)

 

 

 

 

INDEX3

( P1-19, P1-20 )

P2-38 (V3)

P2-54 (T3)

 

 

 

 

INDEX4

( P1-21, P1-22 )

P2-39 (V4)

P2-55 (T4)

 

 

 

 

INDEX5

( P1-23, P1-24 )

P2-40 (V5)

P2-56 (T5)

 

 

 

 

INDEX6

( P1-25, P1-26 )

P2-41 (V6)

P2-57 (T6)

 

 

 

 

INDEX7

( P1-27, P1-28 )

P2-42 (V7)

P2-58 (T7)

 

 

 

 

INDEX8

( P1-29, P1-30 )

P2-43 (V8)

P2-59 (T8)

 

 

 

 

„Digital I/O Signal Setting

 

DI Signal

Parameter Setting

 

Explanation

DI1 (SON)

P2-10 = 101

 

Servo ON

 

 

 

 

 

DI2 (AUTOR)

P2-11 = 142

 

Auto run input

 

 

 

 

 

DI3 (STEPD)

P2-12 = 140

 

Step down input

 

 

 

 

 

(STEPU)

P2-12 = 139

 

Step up input

 

 

 

 

 

(STEPB)

P2-12 = 141

 

Step back input.

 

 

 

 

 

DI4 (SHOM)

P2-13 = 127

 

Move to “Home”

 

 

 

 

 

DI5 (ORGP)

P2-14 = 124

 

Reference “Home” sensor

 

 

 

 

 

 

DI6

(CWL)

P2-15 = 22 (contact “b”)

 

Reverse Inhibit limit

 

 

 

 

 

 

DI7

(CCWL)

P2-16 = 23 (contact “b”)

 

Forward Inhibit limit

 

 

 

 

 

DI8 (EMGS)

P2-17 = 21 (contact “b”)

 

Emergency stop

 

 

 

 

 

 

 

DO Signal

 

Parameter Setting

 

Explanation

 

DO1

 

P2-18 = 101

 

 

 

 

 

 

 

 

 

DO2

 

P2-19 = 103

Please refer to “Definition of DO Signals” in the

 

 

 

 

 

DO3

 

P2-20 = 109

 

 

following section.

 

 

 

 

 

DO4

 

P2-21 = 105

 

 

 

 

 

 

 

 

 

 

 

DO5

 

P2-22 = 107

 

 

 

 

 

 

 

 

12-26

Revision March 2008, Doc. Name: 2007PDD23000011

Page 325