Delta Electronics none manual RTU Mode Command message Response message, Adr Cmd

Models: none

1 355
Download 355 pages 2.82 Kb
Page 255
Image 255

Chapter 8 MODBUS CommunicationsASDA-AB Series

RTU Mode:

 

Command message:

Response message:

ADR

01H

CMD

03H

Starting data

02H (Upper bytes)

address

00H (Lower bytes)

 

 

Number of data

00H

(Count by word)

02H

 

 

CRC Check Low

C5H (Lower bytes)

 

 

CRC Check High

B3H (Upper bytes)

 

 

Command code: 06H, write 1 word

ADR

CMD

Number of data (Count by byte)

Contents of starting

data address

0200H

Contents of second

data address

0201H

CRC Check Low

CRC Check High

01H

03H

04H

00H (Upper bytes) B1H (Lower bytes) 1FH (Upper bytes) 40H (Lower bytes) A3H (Lower bytes) D4H (Upper bytes)

For example, writing 100 (0064H) to starting data address 0200H of ASDA-AB series with address 01H.

ASCII Mode:

Command message:

STX

‘:’

ADR

‘0’

 

‘1’

 

CMD

‘0’

 

‘6’

 

 

‘0’

 

 

Starting data

‘2’

address

‘0’

 

 

 

‘0’

 

‘0’

 

 

Content of data

‘0’

 

‘6’

 

 

 

 

‘4’

LRC Check

‘9’

 

‘3’

 

End 1

(0DH)(CR)

End 0

(0AH)(LF)

 

 

Response message:

STX

‘:’

ADR

‘0’

‘1’

 

CMD

‘0’

‘6’

 

 

‘0’

Starting data

‘2'

address

‘0’

 

‘0’

 

‘0’

Content of data

‘0’

‘6’

 

 

‘4’

LRC Check

‘9’

‘3’

 

End 1

(0DH)(CR)

End 0

(0AH)(LF)

 

 

8-12

Revision March 2008, Doc. Name: 2007PDD23000011

Page 255
Image 255
Delta Electronics none manual RTU Mode Command message Response message, Adr Cmd, Ascii Mode Command message