Chapter 5 Trial Run and Tuning ProcedureASDA-AB Series

The position command is selected by POS0 ~ POS2. Please refer to the following table:

Position

POS2

POS1

POS0

CTRG

Parameters

Moving Speed

Description

Command

 

 

 

 

 

 

Register

 

Internal

0

0

0

 

 

P1-15

P2-36 (V1)

Rotation No. (+/- 30000)

 

 

Position 1

 

 

P1-16

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

0

0

1

 

 

P1-17

P2-37 (V2)

Rotation No. (+/- 30000)

 

 

Position 2

 

 

P1-18

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

0

1

0

 

 

P1-19

P2-38 (V3)

Rotation No. (+/- 30000)

 

 

Position 3

 

 

P1-20

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

0

1

1

 

 

P1-21

P2-39 (V4)

Rotation No. (+/- 30000)

 

 

Position 4

 

 

P1-22

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

1

0

0

 

 

P1-23

P2-40 (V5)

Rotation No. (+/- 30000)

 

 

Position 5

 

 

P1-24

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

1

0

1

 

 

P1-25

P2-41 (V6)

Rotation No. (+/- 30000)

 

 

Position 6

 

 

P1-26

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

1

1

0

 

 

P1-27

P2-42 (V7)

Rotation No. (+/- 30000)

 

 

Position 7

 

 

P1-28

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

1

1

1

 

 

P1-29

P2-43 (V8)

Rotation No. (+/- 30000)

 

 

Position 8

 

 

P1-30

Pulse No. (+/- max cnt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: indicates OFF (Normally Open); 1: indicates ON (Normally Closed)

The users can set the value of these 8 groups of commands (P1-15 ~ P1-30) freely. The command can be absolute position command (P1-33 =0) or relative position command (P1-33 =1).

For example:

Set P1-33 to 1 (Absolute position command)

(The new setting will be effective after the servo drive is restarted (after switching power off and on))

Set P1-15 to 1 (rotation number)

Set P1-16 to 0 (pulse number)

The command of internal position 1: P1-15 Rotation No. + P1-16 Pulse No.

Set P1-17 to 10 (rotation number)

Set P1-18 to 0 (pulse number)

The command of internal position 2: P1-17 Rotation No. + P1-18 Pulse No.

Set P1-19 to -10 (rotation number)

Set P1-20 to 0 (pulse number)

The command of internal position 3: P1-19 Rotation No. + P1-20 Pulse No.

Set P1-21 to 100 (rotation number)

Set P1-22 to 0 (pulse number)

The command of internal position 4: P1-21 Rotation No. + P1-22 Pulse No.

Set P1-23 to -1000 (rotation number)

Set P1-24 to 0 (pulse number)

The command of internal position 5: P1-23 Rotation No. + P1-24 Pulse No.

5-12

Revision March 2008, Doc. Name: 2007PDD23000011