Chapter 7 Servo Parameters

7.1Definition

There are following five groups for drive parameters:

Group 0: Monitor parameter

(example: P0-xx)

Group 1: Basic parameter

(example: P1-xx)

Group 2: Extension parameter

(example: P2-xx)

Group 3: Communication parameter

(example: P3-xx)

Group 4: Diagnosis parameter

(example: P4-xx)

Abbreviation of control modes:

Pt

:

Position control mode (command from external signal)

Pr

:

Position control mode (command from internal signal)

S: Speed control mode

T: Torque control mode

Explanation of symbols (marked after parameter)

()

Read-only register, such as P0-00, P0-01, P4-00.

(▲)

Parameter cannot be set when Servo On (when the servo drive is enabled), such as P1-00, P2-32.

(●)

Parameter is effective only after the servo drive is restarted (after switching power off and on), such

 

as P1-01, P1-33.

(■)

Parameter setting values are not retained when power is off, such as P3-06.