Delta Electronics none manual User-defined DI and do signals, Wiring Diagrams of I/O Signals CN1

Models: none

1 355
Download 355 pages 2.82 Kb
Page 53
Image 53

Chapter 3 Connections and WiringASDA-AB Series

3.3.3 User-defined DI and DO signals

If the default DI and DO signals could not be able to fulfill users’ requirements, there are still user- defined DI and DO signals. The setting method is easy and they are all defined via parameters. The user-defined DI and DO signals are defined via parameters P2-10 to P2-17 and P2-18 to P2-22.

Please refer to the following Table 3.I for the settings.

Table 3.I User-defined DI and DO signals

Signal Name

Pin No.

Parameter

 

 

 

 

 

DI1-

9

P2-10

 

 

 

 

 

DI2-

10

P2-11

 

 

 

 

 

DI3-

34

P2-12

 

 

 

 

DI

DI4-

8

P2-13

 

 

 

DI5-

33

P2-14

 

 

 

 

 

 

DI6-

32

P2-15

 

 

 

 

 

DI7-

31

P2-16

 

 

 

 

 

DI8-

30

P2-17

 

 

 

 

Signal Name

Pin No.

Parameter

 

 

 

 

 

DO1+

7

P2-18

 

 

 

 

DO1-

6

 

 

 

 

 

 

 

DO2+

5

P2-19

 

 

 

 

DO2-

4

 

 

 

 

 

 

DO

DO3+

3

P2-20

 

 

DO3-

2

 

 

 

 

 

 

 

DO4+

1

P2-21

 

 

 

 

DO4-

26

 

 

 

 

 

 

 

DO5+

28

P2-22

 

 

 

 

DO5-

27

 

 

 

 

 

 

3.3.4 Wiring Diagrams of I/O Signals (CN1)

The valid voltage range of analog input command in speed and torque mode is -10V ~+10V. The command value can be set via relevant parameters.

C1: Speed / Torque analog signal input

C2: Analog monitor output (MON1, MON2)

3-26

Revision March 2008, Doc. Name: 2007PDD23000011