P2 - 31

Chapter 7 Servo ParametersASDA-AB Series

AUT1

Auto Mode Responsiveness Level

Communication Addr.: 021FH

 

 

 

Default: 44

Related Section:

Applicable Control Mode: ALL

Section 5.6, Section 6.3.6

Unit: N/A

 

 

Range: 0 ~ FF

Settings:

This parameter allows the users to set the responsiveness level setting of auto-tuning mode. Users can control the responsiveness according to application condition. When the setting value is higher, the responsiveness is higher.

A

B

not used

A:No function

B:Responsiveness level of auto-tuning mode

0 ~ FF: 0 indicates the lowest setting and F indicates the highest setting (total 16 settings available).

NOTE

1)This parameter is activated by P2-32.

2)Please refer to Section 5.6 for the tuning procedure and the related settings.

Revision March 2008, Doc. Name: 2007PDD23000011

7-61