Chapter 12 Application ExamplesASDA-AB Series

12.6 Feed Step Control

„Relevant Parameters Description

 

Parameter

Communication

Parameter Description

 

Address

 

 

 

 

P1-01

0101H

Control Mode and Output Direction

 

 

 

001: Forward torque in Pr mode

 

 

 

101: Reverse torque in Pr mode

 

 

 

 

 

P1-12

010CH

Torque Limit Setting

 

 

 

Torque decrease value is represented by a percentage of rated

 

 

 

torque.

 

P1-33

0121H

Position Control Mode (Pr)

 

 

 

2: Forward operation search feed step

 

 

 

3: Reverse operation search feed step

 

 

 

4: Short-pass search feed step

 

 

 

 

 

P1-34

0122H

Acceleration Time

 

 

 

1st to 3rd step Acceleration time (When parameter P1-36 is set to 0,

 

 

 

accel / decel function is disabled, i.e. P1-34, P1-35 is disabled)

 

P1-35

0123H

Deceleration Time

 

 

 

1st to 3rd step Deceleration time (When parameter P1-36 is set to 0,

 

 

 

accel / decel function is disabled, i.e. P1-34, P1-35 is disabled)

 

P1-36

0124H

Accel /Decel S-curve

 

 

 

When parameter P1-36 is set to 0, accel / decel function is disabled,

 

 

 

i.e. P1-34, P1-35 is disabled.

 

 

 

 

 

P1-44

012CH

Electronic Gear Ratio (1st Numerator) (N1)

 

 

 

If the electronic gear deceleration ratio is 1/75, set numerator to 75

 

 

 

 

 

P1-45

012DH

Electronic Gear Ratio (Denominator)

 

 

 

 

 

P1-47

012FH

Homing Mode

 

 

 

202: When (MD1, MD0)=(OFF, ON), Forward Homing

 

 

 

203: When (MD1, MD0)=(OFF, ON), Reverse Homing

 

 

 

 

12-14

 

Revision March 2008, Doc. Name: 2007PDD23000011

Page 313
Image 313
Delta Electronics none manual Feed Step Control, „ Relevant Parameters Description