Delta Electronics none manual DI Diagnosis Operation, Do Diagnosis Operation

Models: none

1 355
Download 355 pages 2.82 Kb
Page 77
Image 77

Chapter 4 Display and OperationASDA-AB Series

4.4.5 DI Diagnosis Operation

Following the setting method in Figure 4.7 can perform DI diagnosis operation (parameter P4-07). According to the ON and OFF status of the digital inputs DI1 to DI8, the corresponding status will display on the servo drive LED display. When the segment lit and display on the screen, it means that the corresponding digital input signal is ON. (Please also refer to Figure 4.7)

Figure 4.7

4.4.6 DO Diagnosis Operation

Following the setting method in Figure 4.8 can perform DO diagnosis operation (parameter P4-09). According to the ON and OFF status of the digital outputs DO1 to DO5, the corresponding status will display on the servo drive LED display. When the segment lit and display on the screen, it means that the corresponding digital input signal is ON. (Please also refer to Figure 4.8)

Figure 4.8

4-10

Revision March 2008, Doc. Name: 2007PDD23000011

Page 77
Image 77
Delta Electronics none manual DI Diagnosis Operation, Do Diagnosis Operation