P2 - 10

 

 

Chapter 7 Servo ParametersASDA-AB Series

 

 

 

 

 

DI1

Digital Input Terminal 1 (DI1)

 

Communication Addr.: 020AH

 

 

 

 

 

 

Default: 101

 

Related Section:

Applicable Control Mode: ALL

 

Table 7.A

Unit: N/A

 

 

 

 

Range: 0 ~ 147

 

 

 

Settings:

This parameter is used to determine the function and status of DI1.

A

B

not used

A: DI Function Settings: For the setting value of P2- 10 ~ P2-17, please refer to Table 7.A.

B: DI Enabled Status Settings:

0:Normally closed (contact b)

1:Normally open (contact a)

Please re-start the servo drive after parameters have been changed.

P2 - 11

DI2

Digital Input Terminal 2 (DI2)

Communication Addr.: 020BH

 

 

 

Default: 104

Related Section:

Applicable Control Mode: ALL

Table 7.A

Unit: N/A

 

 

Range: 0 ~ 147

Settings: See P2-10 for explanation.

P2 - 12

DI3

Digital Input Terminal 3 (DI3)

Communication Addr.: 020CH

 

 

 

Default: 116

Related Section:

Applicable Control Mode: ALL

Table 7.A

Unit: N/A

 

 

Range: 0 ~ 147

Settings: See P2-10 for explanation.

Revision March 2008, Doc. Name: 2007PDD23000011

7-55