Chapter 7 Servo ParametersASDA-AB Series

P2 - 44

 

DOM

Digital Output Mode Setting

Communication Addr.: 022CH

 

 

 

 

 

 

 

Default: 0

 

Related Section:

 

 

Applicable Control Mode: Pr

Section 12.6

 

 

Unit: N/A

 

 

Range: 0 ~ 1

Settings:

This parameter determines that the digital output equals the setting value of P2-18 ~ P2-22 or INDEX positions when using feed step control function and in internal auto running mode (See Chapter 12 for explanation).

0:General output mode, digital output function is defined by the setting value of P2-18 ~ P2-22.

1:Combination output mode

When the users want to use feed step control function, this output mode must be selected. Otherwise, the feed step control function can not be used normally. (Refer to Section 12.6)

When the users want to use internal auto running mode function, this output mode must be selected. Otherwise, the output signal can not be converted to combination output signal normally. (Refer to Section 12.7)

P2 - 45

DOD

Combination Output Signal Delay Time

Communication Addr.: 022DH

 

 

 

Default: 1

 

Related Section:

Applicable Control Mode: Pr

Section 12.6

Unit: 4ms

 

 

Range: 0 ~ 250

Settings:

This parameter can be used only when P2-44 is set to 1. The users can use this parameter to set the ON time delay when positioning is completed.

P2 - 46

FSN

Feed Step Number

Communication Addr.: 022EH

 

 

 

Default: 6

 

Related Section:

Applicable Control Mode: Pr

Section 12.6

Unit: sec

 

 

Range: 2 ~ 32

 

7-66

Revision March 2008, Doc. Name: 2007PDD23000011