Delta Electronics none manual Dph, Nlp, Pwm

Models: none

1 355
Download 355 pages 2.82 Kb
Page 128
Image 128

P2 - 24

 

Chapter 6 Control Modes of OperationASDA-AB Series

 

 

 

 

DPH

Notch Filter Attenuation Rate

Communication Addr.: 0218H

 

(Resonance Suppression)

 

 

 

 

Default: 0

 

Related Section:

 

Applicable Control Mode: P/S/T

Section 6.3.7

Unit: dB

 

 

 

Range: 0 ~ 32

Settings: 0: Disabled

P2 - 25

NLP

Low-pass Filter Time Constant

Communication Addr.: 0219H

(Resonance Suppression)

 

 

Default: 2

(1kW and below models) or

Related Section:

5

(above 1kW models)

Section 6.3.7

Applicable Control Mode: P/S/T

Unit: ms

Range: 0 ~ 1000

Settings:

This parameter is used to set low-pass filter time constant of resonance suppression. 0: Disabled

Speed Control Block Diagram

Feed forward

differentiator Gain P2-07

PI Controller (Proportional and Integral Controller)

P2-04,2-06

Low-pass

Filter

P2-25

Current Sensor

Current Controller

Notch Filter

PWM

P2-23,P2-24

 

 

Torque

 

Load

Speed estimator

Encoder