Chapter 10 TroubleshootingASDA-AB Series

10.2 Potential Cause and Corrective Actions

Servo Drive Fault Messages

: Overcurrent

 

Potential Cause

Checking Method

Corrective Actions

Short-circuit at drive

1. Check the wiring connections between drive

Repair the short-circuited and avoid

output (U, V, W)

and motor.

metal conductor being exposed.

2. Check if the wire is short-circuited.

 

 

 

 

 

 

 

 

 

Motor wiring error

Check if the wiring steps are all correct when

Follow the wiring steps in the user

connecting motor to drive.

manual to reconnect wiring.

 

 

 

IGBT error

Heat sink overheated

Please contact your distributor for

assistance or contact with Delta.

 

 

 

 

Control parameter

Check if the setting value exceeds the factory

Set the setting back to factory

default setting and then reset and

setting error

default setting.

adjust the parameter setting again.

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Ensure that input command

Control command

Check if the control input command is unstable

frequency is stable (too much

setting error

(too much fluctuation).

fluctuation).

 

 

 

 

2. Activate filter function.

 

 

: Overvoltage

 

 

 

 

 

 

 

 

 

 

 

 

Potential Cause

Checking Method

Corrective Actions

The main circuit voltage

Use voltmeter to check whether the input

 

has exceeded its

voltage falls within the rated input voltage. (For

Use correct power supply or

maximum allowable

voltage specification, please refer to section

stabilizing power.

value.

11.1 in Chapter11.)

 

Input power error

Use voltmeter to check whether the input

Use correct power supply or

(Incorrect power input)

voltage is within the specified limit.

stabilizing power.

 

 

: Undervoltage

 

 

 

 

 

 

 

 

 

 

 

 

Potential Cause

Checking Method

Corrective Actions

The main circuit voltage

Check whether the wiring of main circuit input

Reconfirm voltage wiring.

is below its minimum

voltage is normal.

specified value.

 

 

 

 

 

 

No input voltage at

Use voltmeter to check whether input voltage at

Reconfirm power switch.

main circuit.

main circuit is normal.

 

Input power error

Use voltmeter to check whether the input

Use correct power supply or serial

(Incorrect power input)

voltage is within the specified limit.

stabilizing power.

 

 

: Z Pulse shift

 

 

 

 

 

 

 

 

 

 

 

 

Potential Cause

Checking Method

Corrective Actions

Encoder is damage.

Check Encoder for the damage.

Repair or replace the motor.

 

 

 

Encoder is loose.

Examine the Encoder connector.

Install the motor again.

 

 

 

 

 

Revision March 2008, Doc. Name: 2007PDD23000011

10-3

Page 268
Image 268