Delta Electronics none manual Monitor Setting Display

Models: none

1 355
Download 355 pages 2.82 Kb
Page 71
Image 71

Chapter 4 Display and OperationASDA-AB Series

 

Display Message

Description

 

 

 

Negative value display. When the parameter setting is greater

 

 

 

than four digits (for the setting value within the range of less than

 

 

 

five decimal places), after the display value is set, continuously

 

 

 

press SHIFT key for many times and then the lit decimal points

 

 

 

are used to indicate a negative value.

 

 

 

Negative value display. When the parameter setting is less than

 

 

 

five digits (for the setting value within the range of five decimal

 

 

 

places), after the display value is set, continuously press SHIFT

 

 

 

key for many times and then the negative sign will show up to

 

 

 

indicate a negative value.

4.3.5 Monitor Setting Display

When the AC servo drive is applied to power, the LCD display will show the monitor function codes for approximately one second and then enter into the monitor mode. In monitor mode, in order to change the monitor status, the users can press UP or DOWN arrow key or change parameter P0-02 directly to specify the monitor status. When the power is applied, the monitor status depends on the setting value of P0-02. For example, if the setting value of P0-02 is 2 when the power is applied, the monitor function will be Pulse counts of pulse command, the C.P monitor codes will first display and then the pulse number will display after.

P0-02

 

Display Message

 

Description

 

 

Unit

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

Motor feedback pulse number (absolute

 

pulse

 

 

 

 

 

 

 

 

 

value)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

Motor feedback rotation number

 

rev

 

 

 

 

 

 

 

 

 

(absolute value)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Pulse counts of pulse command

pulse

3

Rotation number of pulse command

rev

4

Position error counts

pulse

5

Input frequency of pulse command

r/min

6

Motor speed

r/min

7

Speed input command

Volt

8

Speed input command

r/min

4-4

Revision March 2008, Doc. Name: 2007PDD23000011

Page 71
Image 71
Delta Electronics none manual Monitor Setting Display