Chapter 7 Servo ParametersASDA-AB Series

Table 7.A

Input Function Definition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sign

 

Setting

 

 

 

 

Digital Input Function Description

 

 

 

 

 

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SON

 

01

Servo On. Switch servo to "Servo Ready". Check parameter P2-51.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARST

 

02

Alarm Reset. A number of Faults (Alarms) can be cleared by activating ARST.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAINUP

 

03

Gain switching in speed and position mode. When GAINUP is activated (P2-27 is set

 

 

 

to 1), the gain is switched to the gain multiplied by fluctuation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulse clear (see P2-50). When CCLR is activated, the parameter P2-50 Pulse

 

 

 

 

 

Deviation Clear Mode is executed.

 

 

 

 

 

 

 

 

 

0: Clear position pulse deviation number (available in Pt and Pr mode only)

 

 

CCLR

 

04

1: Clear motor feedback pulse and rotation number (available in Pt and Pr mode only)

 

 

 

2: Clear remaining position pulses and interrupt the motor operation (available Pr

 

 

 

 

 

 

 

 

 

 

mode only).

 

 

 

 

 

 

 

 

 

3: Clear remaining position pulses and interrupt the motor operation. After the motor is

 

 

 

 

 

stopped, activate TPOS signal (available Pr mode only).

 

 

 

 

 

 

 

 

 

Zero speed CLAMP. When this signal is On and the motor speed value is below the

 

 

 

 

 

setting value of P1-38, it is used to lock the motor in the instant position while ZCLAMP

 

 

 

 

 

is On.

 

 

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting value of

 

 

 

 

 

 

 

 

 

 

ZCLAMP

 

05

P1-38 (Zero speed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZCLAMP

 

 

 

 

 

 

 

 

 

 

 

 

 

input signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting value of

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-38 (Zero speed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

CMDINV

 

06

Command input reverse control. When the drive is in Pr, Speed and Torque mode, and

 

 

 

CMDINV is activated, the motor is in reverse rotation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOLD

 

07

Position command pause (Internal position control only). When the drive is in Pr mode

 

 

 

and HOLD is activated, the motor will pause.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command triggered (available in Pr mode only). When the drive is in Pr mode and

 

 

CTRG

 

08

CTRG is activated, the drive will command the motor to move the stored position

 

 

 

which correspond the POS 0, POS 1, POS 2 settings. Activation is triggered on the

 

 

 

 

 

 

 

 

 

 

rising edge of the pulse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque limit enabled. When the drive is in speed and position mode, and TRQLM is

 

 

TRQLM

 

09

activated, it indicates the torque limit command is valid. The torque limit command

 

 

 

 

 

source is internal parameter or analog voltage.

 

 

 

 

 

 

 

 

 

Speed limit enabled. When the drive is in torque mode and TRQLM is activated, it

 

 

SPDLM

 

10

indicates the speed limit command is valid. The speed limit command source is

 

 

 

 

 

internal parameter or analog voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision March 2008, Doc. Name: 2007PDD23000011

7-89

Page 238
Image 238
Delta Electronics none manual Input Function Definition, Son