Chapter 7 Servo ParametersASDA-AB Series

CWD

Communication Time Out Detection

Communication Addr.: 0304H

 

 

 

Default: 0

 

Related Section:

Applicable Control Mode: ALL

Section 8.2

Unit: N/A

 

 

Range: 0~20

Settings:

0: Disabled

This parameter is used to set the maximum permissible time before detecting a fault due to communication time out. When this parameter is set to a value over than 0, it indicates this function is enabled. However, if not communicating with the servo in this period of time, the servo drive will assume the communication has failed and show the communication error fault message.

P3 - 05

CMM

Communication Selection

Communication Addr.: 0305H

 

 

 

Default: 0

 

Related Section:

Applicable Control Mode: ALL

Section 8.2

Unit: N/A

 

 

Range: 0~2

 

Settings:

 

 

0:RS-232

1:RS-422

2:RS-485

Multiple communication modes RS232, RS-485, RS-422 cannot be used within one communication ring.

Revision March 2008, Doc. Name: 2007PDD23000011

7-79