P1 - 43

Chapter 7 Servo ParametersASDA-AB Series

MBT2

OFF Delay Time of Electromagnetic Brake

Communication Addr.: 012BH

 

 

 

Default: 0

Related Section:

Applicable Control Mode: ALL

Section 6.5.5

Unit: ms

 

Range: 0 ~ 1000

 

Settings:

 

Used to set the period of time between when the servo drive is Off (Servo Off) and when electromagnetic brake output signal (BRKR) is inactivated.

NOTE

1)When MBT2 delay time has not finished and motor speed is lower than the setting value of P1-38, electromagnetic brake interlock signal (BRKR) is closed.

2)When MBT2 delay time has finished and motor speed is still higher than the setting value of P1-38, electromagnetic brake interlock signal (BRKR) is closed.

P1 - 44▲

GR1

Electronic Gear Ratio (1st Numerator) (N1)

Communication Addr.: 012CH

 

 

 

Default: 1

 

Related Section:

Applicable Control Mode: Pt, Pr

Section 6.2.5

Unit: Pulse

 

Range: 1 ~ 32767

 

Settings:

 

 

Multiple-step electronic gear numerator setting. Please refer to P2-60~P2-62.

Revision March 2008, Doc. Name: 2007PDD23000011

7-43

Page 192
Image 192
Delta Electronics none manual MBT2, GR1