11.4 Overload Characteristics

„Overload Protection Function

Overload protection is a built-in protective function to prevent a motor from overheating.

„Occasion of Overload

1.Motor was operated for several seconds under a torque exceeding 100% torque.

2.Motor had driven high inertia machine and had accelerated and decelerated at high frequency.

3.Motor UVW cable or encoder cable was not connected correctly.

4.Servo gain was not set properly and caused motor hunting.

5.Motor holding brake was not released.

„Chart of load and operating time (ECMA-C30401……)

1000

(seconds)

100

 

Operating Time

10

1

 

0.1

0

50

100

150

200

250

300

Load (%) rated torque

Load

Operating

Time

 

120%

139.335s

140%

27.585s

160%

14.235s

180%

8.9625s

200%

6s

220%

4.4925s

240%

3.2925s

260%

2.58s

280%

2.07s

300%

1.6125s