Chapter 12 Application ExamplesASDA-AB Series

12.8 Homing Function

„Relevant Parameters Description

 

Parameter

 

Communication

 

 

 

 

 

 

 

 

 

 

 

Parameter Description

 

 

 

Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1-47

012FH

Homing Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A: Home Sensor Type and Homing Direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B: Homing Moving Method

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C: Homing Enable Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D: Homing Stop Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No use

 

 

 

 

 

 

 

 

 

 

 

P1-48

0130H

1st Speed Setting of High Speed Homing

 

 

 

P1-49

0131H

2nd Speed Setting of Low Speed Homing

 

 

 

P1-50

0132H

Homing Offset Rotation Number

 

 

 

P1-51

0133H

Homing Offset Pulse Number

 

 

 

 

 

 

 

 

 

„Relevant Parameters Description, cont.

Parameter

Communication

Parameter Description

Address

 

 

P1-34

0122H

Acceleration Time

 

 

 

P1-35

0123H

Deceleration Time

 

 

 

P1-36

0124H

Accel /Decel S-curve

 

 

 

„Explanation of Homing Mode

A: Home Sensor Type and Homing Direction

Left or right limit switch can be used as a reference “Home” for homing function. It also can use extra sensor, such as proximity switch or photo switch as reference “Home”. When the servo motor runs within one revolution only, users also can set Z-phase pulse as a reference “Home”.

A=0: Forward homing and CCWL limit input point is regarded as a rough reference “Home”. When home is in position, CCWL will turn into limit input function. If trigger CCWL afterward, the limit alarm will occur. When use limit input point as a rough reference “Home”, we recommend users to set B=0, i.e. return to find Z-phase pulse during homing and regard Z-phase pulse as a precise mechanical “Home”.

A=1: Reverse homing and CWL limit input point is regarded as a rough reference “Home”. When home is in position, CWL will turn into limit input function. If trigger CWL afterward, the limit alarm will occur. When use limit input point as a rough reference “Home”, we recommend users to set B=0, i.e. return to find Z- phase pulse during homing and regard Z-phase pulse as a precise mechanical “Home”.

12-30

Revision March 2008, Doc. Name: 2007PDD23000011

Page 329
Image 329