Chapter 7 Servo ParametersASDA-AB Series

Diagnosis

 

 

 

 

 

 

 

Control

 

Related

 

 

Parameter

Name

Function

Default

Unit

 

Mode

 

Section of

 

 

 

 

 

 

 

User

 

 

 

 

 

 

 

Pt

Pr

S

T

 

 

 

 

 

 

 

 

 

Manual

 

 

P4-00

ASH1

Fault Record (N)

0

N/A

{

{

{

{

 

4.4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-01

ASH2

Fault Record (N-1)

0

N/A

{

{

{

{

 

4.4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-02

ASH3

Fault Record (N-2)

0

N/A

{

{

{

{

 

4.4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-03

ASH4

Fault Record (N-3)

0

N/A

{

{

{

{

 

4.4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-04

ASH5

Fault Record (N-4)

0

N/A

{

{

{

{

 

4.4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-05

JOG

JOG Operation

20

r/min

{

{

{

{

 

4.4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-06▲■

FOT

Force Output Control

0

N/A

{

{

{

{

 

4.4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-07

ITST

Input Status or Force Input

N/A

N/A

{

{

{

{

 

4.4.5

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-08

PKEY

Digital Keypad Input of Servo Drive

N/A

N/A

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-09

MOT

Output Status Display

N/A

N/A

{

{

{

{

 

4.4.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-10

CEN

Adjustment Function

0

N/A

{

{

{

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-11

SOF1

Analog Speed Input Drift

Factory

N/A

{

{

{

{

 

---

 

 

Adjustment 1

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-12

SOF2

Analog Speed Input Drift

Factory

N/A

{

{

{

{

 

---

 

 

Adjustment 2

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-13

TOF1

Analog Torque Drift Adjustment 1

Factory

N/A

{

{

{

{

 

---

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-14

TOF2

Analog Torque Drift Adjustment 2

Factory

N/A

{

{

{

{

 

---

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-15

COF1

Current Detector Drift Adjustment

Factory

N/A

{

{

{

{

 

---

 

 

(V1 phase)

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-16

COF2

Current Detector Drift Adjustment

Factory

N/A

{

{

{

{

 

---

 

 

(V2 phase)

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-17

COF3

Current Detector Drift Adjustment

Factory

N/A

{

{

{

{

 

---

 

 

(W1 phase)

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-18

COF4

Current Detector Drift Adjustment

Factory

N/A

{

{

{

{

 

---

 

 

(W2 phase)

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-19

TIGB

IGBT NTC Calibration

Factory

N/A

{

{

{

{

 

---

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-20

DOF1

Analog Monitor Output Drift

0

mV

{

{

{

{

 

6.4.4

 

 

Adjustment (CH1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-21

DOF2

Analog Monitor Output Drift

0

mV

{

{

{

{

 

6.4.4

 

 

Adjustment (CH2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-22

SAO

Analog Speed Input Offset

0

mV

 

 

{

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4-23

TAO

Analog Torque Input Offset

0

mV

 

 

 

{

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-18

Revision March 2008, Doc. Name: 2007PDD23000011