Chapter 7 Servo ParametersASDA-AB Series

P0 - 09

 

MAP0

Block Data Read / Write Register 0

Communication Addr.: 0009H

 

 

 

 

 

 

 

Default: 407H

Related Section: N/A

 

 

Applicable Control Mode: ALL

 

 

 

Unit: N/A

 

 

 

Range: 100H ~ 417H

 

 

 

Settings:

 

Set the register address in HEX that users want to read and write by using the keypad.

Users can enter the desired register address (0100H ~ 0417H) into P0-09 to P0-16 (0009H ~ 0010H). Then, users can read and write up to 8 continuous specified block data from the communication address 0009H to 0010H through the communication port.

For example, if setting P0-09 to 407 by using the keypad, when the users read and write the data from communication address 0009H, it means that the read and write value is the setting value of parameter P4-07.

P0 - 10

MAP1

Block Data Read / Write Register 1

Communication Addr.: 000AH

 

 

 

Default: 10FH

Related Section: N/A

Applicable Control Mode: ALL

 

Unit: N/A

 

Range: 100H ~ 417H

 

Settings: See P0-09 for explanation.

 

P0 - 11

MAP2

Block Data Read / Write Register 2

Communication Addr.: 000BH

 

 

 

Default: 110H

Related Section: N/A

Applicable Control Mode: ALL

 

Unit: N/A

 

Range: 100H ~ 417H

 

Settings: See P0-09 for explanation.

 

P0 - 12

MAP3

Block Data Read / Write Register 3

Communication Addr.: 000CH

 

 

 

Default: 224H

Related Section: N/A

Applicable Control Mode: ALL

 

Unit: N/A

 

Range: 100H ~ 417H

 

Settings: See P0-09 for explanation.

 

7-24

Revision March 2008, Doc. Name: 2007PDD23000011

Page 173