4.7.2 Setting the Admin Network

To use the Admin Tool or Central Admin Server for the scanner, perform the connection settings.

1.Select the [Network Settings] tab on the top menu.

2.Select the [Admin Network] tab on the left side menu.

The "Admin Network" screen appears.

For Central Admin Console, contents of the SSL Certificate are not shown.

3.Enter a port number from 1 to 65535, to be used by the scanner to communicate with the Admin Tool or Central Admin Server.

The default setting is 80.

ATTENTION

zPort numbers 135, 139, 445, and numbers from 1025 to 1124, can- not be specified as they are already reserved in the scanner.

zIf port numbers other than HTTP: 80, HTTPS: 443 are to be speci- fied, it is recommended that numbers over 5000 are used. If a port number lower than 5000 is specified, verify the Admin Tool connec- tivity with the port number first.