HP unix manual The Voltage Regulator Modules, Replacing a Voltage Regulator Module

Models: unix

1 204
Download 204 pages 13.99 Kb
Page 122
Image 122

Field Replaceable Units

FRU Removal and Replacement

As shown in Figure 4-48, the top voltage regulator module is the master, and the bottom one nearest the chassis floor is the slave.

Figure 4-48. The Voltage Regulator Modules

Voltage Regulator

Modules:

Master (Top)

Slave (Bottom)

4.Press down on the ejector tabs located on each side of the voltage regulator module (master or slave) to release it from the system board connector.

5.Grasp the voltage regulator module (master or slave) firmly and pull outward to release it from the system board connector.

Replacing a Voltage Regulator Module

WARNING To prevent injury, unplug the workstation’s power cord from the electrical outlet before replacing a voltage regulator module.

Before replacing a voltage regulator module, ensure that it is the correct one (master or slave) for insertion into the correct connector on the system board. See Figure 4-49 to identify the two different voltage regulator modules (master and slave).

NOTE

The master and the slave voltage regulator modules differ in the placement of

 

the notch in their gold edge connectors, as shown in Figure 4-49. This notch

 

fits the notch-key of the system board’s connector into which each voltage

 

regulator module (master or slave) fits. The notches and notch-keys prevent

 

you from installing a voltage regulator module into the wrong connector.

 

 

Refer to Figure 4-48 for the correct system board connector (the top connector for the master, or the bottom connector nearest the chassis floor for the slave) in which to insert the voltage regulator module you need to replace.

122

Chapter 4

Page 122
Image 122
HP unix manual The Voltage Regulator Modules, Replacing a Voltage Regulator Module