Field Replaceable Units
FRU Removal and Replacement
Power Supply
This section explains how to remove and replace the power supply in the B2000 workstation.
Removing the Power Supply
WARNING To prevent injury, unplug the workstation’s power cord from the electrical outlet before removing the power supply.
Perform the following steps to remove the power supply:
1.Open the left side panel of the workstation as shown in the section “Opening the Left Side Panel.”
2.Unplug the three power supply cables from the system board.
3.Remove the rear cover of the CD drive bay and disconnect the power cable. To do this, see the section “Removing and Replacing a CD Drive” on page 91.
4.Remove the rear cover of the floppy disk drive bay and disconnect the power cable, if the optional floppy disk drive is installed. To do this, see the section “Removing a Floppy Disk Drive” on page 96.
5.Detach the bundled power cables from the cable management clips on the chassis floor. See Figure
Figure 4-46. Screws Holding the Power Supply in Place
Four
Torx Screws
Power Supply | Cable Management Clips |
6.Remove the four
7.Slide the power supply towards the front of the workstation. You must disengage the hook on the bottom of the power supply from the support strap in the chassis floor. Then remove the power supply from the workstation chassis.
Chapter 4 | 119 |