Troubleshooting

 

 

 

 

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

FLT

7611

DIMM

ECC single data

Memory ECC test failed to detect

 

 

 

 

single-bit data error.

 

 

 

 

 

FLT

7612

DIMM

ECC single ECC

Memory ECC test failed to detect

 

 

 

 

single-bit ECC error.

 

 

 

 

 

FLT

7613

DIMM

ECC multipl data

Memory ECC test failed to detect

 

 

 

 

multiple-bit data error.

 

 

 

 

 

FLT

7614

DIMM

ECC multpl signl

Memory ECC test failed to signal

 

 

 

 

multiple-bit error.

 

 

 

 

 

FLT

7800

SYS BD

mem err summary

Printing memory error summary word to

 

 

 

 

RS-232.

 

 

 

 

 

FLT

7801

SYS BD

bus ctrl par err

System bus (Runway) control parity error

 

 

 

 

detected.

 

 

 

 

 

FLT

7802

SYS BD

bus addr par err

System bus (Runway) address parity error

 

 

 

 

detected.

 

 

 

 

 

FLT

7803

SYS BD

bus data par err

System bus (Runway) data parity error

 

 

 

 

detected.

 

 

 

 

 

FLT

7804

SYS BD

mem out of range

Memory access outside configured

 

 

 

 

memory space.

 

 

 

 

 

FLT

7805

SYS BD

bus broadcst err

System bus (Runway) broadcast error

 

 

 

 

detected.

 

 

 

 

 

FLT

7806

SYS BD

mem addr par err

Memory bus address parity error

 

 

 

 

detected.

 

 

 

 

 

FLT

7807

SYS BD

mem ctlr stat wd

Printing memory controller status word to

 

 

 

 

RS-232.

 

 

 

 

 

FLT

781s

SYS BD

DIMM s uncor err

Uncorrectable ECC error detected in

 

 

 

 

DIMM s.

 

 

 

 

 

FLT

782s

SYS BD

DIMM s corr err

Correctable ECC error detected in DIMM

 

 

 

 

s.

 

 

 

 

 

FLT

7840

SYS BD

unexpected HPMC

Unexpected HPMC detected.

 

 

 

 

 

FLT

7841

SYS BD

mem status invld

Memory error status word is invalid.

 

 

 

 

 

FLT

7842

SYS BD

mem summ invalid

Memory summary word is invalid.

 

 

 

 

 

FLT

7843

SYS BD

fwd prog invalid

Memory forward progress word is invalid.

 

 

 

 

 

FLT

7844

SYS BD

mem HPMC summ wd

Printing memory error summary word to

 

 

 

 

RS-232.

 

 

 

 

 

FLT

7845

SYS BD

mem ctlr stat wd

Printing memory controller status word to

 

 

 

 

RS-232.

 

 

 

 

 

Chapter 3

65

Page 65
Image 65
HP unix manual Memory ECC test failed to detect