Troubleshooting

 

 

 

 

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

FLT

1nBA

SYS BD

monarch CPU fail

The monarch CPU failed.

 

 

 

 

 

FLT

1nBB

SYS BD

bad CPUn number

The CPU identifier was out of range.

 

 

 

 

 

FLT

1nBF

SYS BD

CPUn halt boot

Bootstrap failure--machine halted.

 

 

 

 

 

INI

1nCA

SYS BD

CPUn sys bus arb

Monarch CPU is initializing the system

 

 

 

 

bus arbitration.

 

 

 

 

 

WRN

1nCD

SYS BD

CPUn deconfig

CPU n deconfigured itself.

 

 

 

 

 

WRN

1nCE

SYS BD

CPUn extinguish

PDC_PROC halted CPU n.

 

 

 

 

 

FLT

1nCF

SYS BD

slaven failed

Slave CPU n failed self-test.

 

 

 

 

 

WRN

1mDs

SYS BD

slaves deconfig

Monarch CPU m deconfigured slave CPU

 

 

 

 

s.

 

 

 

 

 

WRN

1nEF

SYS BD

CPUn slftst warn

CPU n detected a non-fatal error during

 

 

 

 

its self-tests.

 

 

 

 

 

WRN

1mFs

SYS BD

monm stop slaves

Monarch CPU m halted slave CPU s.

 

 

 

 

 

INI

1nFC

SYS BD

CPUn sync’ing

CPU n is synchronizing with the rest of

 

 

 

 

the system.

 

 

 

 

 

INI

1nFD

SYS BD

CPUn stat wd tst

CPU n is testing the system status word.

 

 

 

 

 

FLT

1nFF

SYS BD

monarchn selftst

Monarch CPU n failed self-test.

 

 

 

 

 

TST

2n20

SYS BD

CPUn icache RAM

CPU n is starting its instruction cache

 

 

 

 

RAM self-test.

 

 

 

 

 

FLT

2n25

SYS BD

CPUn ic ld d err

CPU n detected a data error during data

 

 

 

 

cache load.

 

 

 

 

 

FLT

2n26

SYS BD

CPUn ic ld t err

CPU n detected a tag error during data

 

 

 

 

cache load.

 

 

 

 

 

TST

2n30

SYS BD

CPUn icache tag

CPU n is starting its instruction cache tag

 

 

 

 

self-test.

 

 

 

 

 

TST

2n40

SYS BD

CPUn icache par

CPU n is starting its instruction cache

 

 

 

 

parity detection self-test.

 

 

 

 

 

TST

2n50

SYS BD

CPUn dc stor que

CPU n is starting its data cache store

 

 

 

 

queue self-test.

 

 

 

 

 

FLT

2n51

SYS BD

CPUn dc st q err

CPU n detected an error during its data

 

 

 

 

cache store queue self-test.

 

 

 

 

 

TST

2n70

SYS BD

CPUn dcache RAM

CPU n is starting its data cache RAM

 

 

 

 

self-test.

 

 

 

 

 

TST

2n80

SYS BD

CPUn dcache tag

CPU n is starting its data cache tag

 

 

 

 

self-test.

 

 

 

 

 

Chapter 3

57

Page 57
Image 57
HP unix manual Monarch CPU failed