HP unix manual Error detected during boot device I/O

Models: unix

1 204
Download 204 pages 13.99 Kb
Page 67
Image 67

 

 

 

 

Troubleshooting

 

 

 

 

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

WRN

80F7

EXT IO

boot IO error

Error detected during boot device I/O.

 

 

 

 

 

WRN

80F8

EXT IO

invalid boot dev

Invalid boot device class; bad IODC?

 

 

 

 

 

WRN

80FC

EXT IO

invalid boot dev

Unexpected error; bad IODC?

 

 

 

 

 

INI

8800

IOCARD

PCI BusWlk start

Starting PCI bus and device discovery.

 

 

 

 

 

INI

88r1

IOCARD

PCI Rope r walk

Starting PCI bus and device discovery on

 

 

 

 

Rope r.

 

 

 

 

 

INI

8802

IOCARD

PCI BusWalk done

PCI bus and device discovery complete.

 

 

 

 

 

INI

8803

SYS BD

PCI alloc done

Done allocating address space for PCI

 

 

 

 

devices.

 

 

 

 

 

INI

8804

SYS BD

PCI config done

Done configuring PCI devices.

 

 

 

 

 

WRN

881r

IO BD

R2PCIr not found

Rope-to-PCI bridge r not found.

 

 

 

 

 

FLT

881r

IO BD

R2PCIr not found

Rope-to-PCI bridge r not found.

 

 

 

 

 

WRN

882r

IO BD

R2PCIr not found

Rope-to-PCI bridge r initialization failed.

 

 

 

 

 

FLT

882r

IO BD

Roper init err

Rope-to-PCI bridge r initialization failed.

 

 

 

 

 

WRN

883r

IO BD

Roper config err

PCI configuration failed below

 

 

 

 

Rope-to-PCI bridge r.

 

 

 

 

 

FLT

883r

IO BD

Roper config err

Rope r configuration failed.

 

 

 

 

 

INI

884r

EXT IO

Roper debug tggl

Rope r debug register toggled.

 

 

 

 

 

FLT

884r

EXT IO

Roper tgl fail

Rope r debug register toggle failed.

 

 

 

 

 

INI

8850

SYS BD

early rope0 init

Initializing rope 0 for early RS-232

 

 

 

 

output.

 

 

 

 

 

FLT

8850

SYS BD

rope0 init fail

Couldn’t initialize rope 0.

 

 

 

 

 

INI

8860

SYS BD

rope0 init done

Rope 0 initialization complete.

 

 

 

 

 

INI

8870

IO BD

early R2PCI init

Initializing Rope-to-PCI bridge 0 for early

 

 

 

 

RS-232 output.

 

 

 

 

 

FLT

8870

IO BD

R2PCI init fail

Couldn’t initialize Rope-to-PCI bridge 0.

 

 

 

 

 

INI

8880

IO BD

R2PCI init done

Rope-to-PCI bridge 0 initialization

 

 

 

 

complete.

 

 

 

 

 

INI

8890

IO BD

early Super init

Initializing Super-I/O for early RS-232

 

 

 

 

output.

 

 

 

 

 

FLT

8890

IO BD

Super init fail

Couldn’t initialize Super-I/O.

 

 

 

 

 

INI

88A0

IO BD

Super init done

Super-I/O initialization complete.

 

 

 

 

 

Chapter 3

67

Page 67
Image 67
HP unix manual Error detected during boot device I/O