Troubleshooting

 

 

 

 

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

OFF

CBE2

IO BD

PCI SERR#; OV

A PCI device asserted SERR# multiple

 

 

 

 

times.

 

 

 

 

 

OFF

CBE3

IO BD

Unknown PCI err

Unknown PCI error detected.

 

 

 

 

 

OFF

CBE6

SYS BD

AtoE rope perr

Parity error between system I/O controller

 

 

 

 

and Rope-to-PCI bridge.

 

 

 

 

 

OFF

CBE7

IO BD

R2PCI intrnl err

Rope-to-PCI bridge internal data error.

 

 

 

 

 

OFF

CBE8

SYS BD

AtoE rope perr

Command parity error between system

 

 

 

 

I/O controller and Rope-to-PCI bridge.

 

 

 

 

 

OFF

CBE9

IO BD

Unknown Rope err

Unknown rope error occurred.

 

 

 

 

 

FLT

CBF0

SYS BD

HPMC initiated

A High-Priority Machine Check entered

 

 

 

 

the firmware HPMC handler.

 

 

 

 

 

FLT

CBF1

SYS BD

no OS HPMC IVA

There is no HPMC vector for the

 

 

 

 

operating system. Firmware will halt the

 

 

 

 

CPU, requiring a power cycle to recover.

 

 

 

 

 

FLT

CBF2

SYS BD

bad OS HPMC len

The size of the operating system HPMC

 

 

 

 

handler is invalid. Firmware will halt the

 

 

 

 

CPU, requiring a power cycle to recover.

 

 

 

 

 

FLT

CBF3

SYS BD

bad OS HPMC addr

The operating system HPMC handler

 

 

 

 

vector is invalid. Firmware will halt the

 

 

 

 

CPU, requiring a power cycle to recover.

 

 

 

 

 

FLT

CBF4

SYS BD

bad OS HPMC cksm

The operating system HPMC handler

 

 

 

 

failed the checksum test. Firmware will

 

 

 

 

halt the CPU, requiring a power cycle to

 

 

 

 

recover.

 

 

 

 

 

FLT

CBF5

SYS BD

OS HPMC vector 0

The size of the operating system HPMC

 

 

 

 

handler is zero. Firmware will halt the

 

 

 

 

CPU, requiring a power cycle to recover.

 

 

 

 

 

WRN

CBFA

SYS BD

prev HPMC logged

Firmware detected unread PIM data from

 

 

 

 

a previous HPMC and will overwrite it.

 

 

 

 

 

FLT

CBFB

SYS BD

brnch to OS HPMC

Branching to the operating system HPMC

 

 

 

 

handler.

 

 

 

 

 

FLT

CBFC

SYS BD

OS HPMC br err

Branch to the operating system HPMC

 

 

 

 

handler failed. Firmware will halt the

 

 

 

 

CPU, requiring a power cycle to recover.

 

 

 

 

 

FLT

CBFD

SYS BD

unknown check

The firmware trap handler didn’t detect

 

 

 

 

an HPMC, LPMC, or TOC.

 

 

 

 

 

FLT

CBFE

SYS BD

HPMC during TOC

A High-Priority Machine Check occurred

 

 

 

 

during Transfer of Control processing.

 

 

 

 

 