HP unix manual Multiple memory errors detected

Models: unix

1 204
Download 204 pages 13.99 Kb
Page 66
Image 66

Troubleshooting

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

Ostat

Code

FRU

Message

Description

 

 

 

 

 

FLT

7846

SYS BD

mem err overflow

Multiple memory errors detected.

 

 

 

 

 

FLT

7848

SYS BD

addr not mapped

Memory address outside configured

 

 

 

 

memory space.

 

 

 

 

 

FLT

785s

DIMM

MBE in DIMM s

Destructive memory test detected an

 

 

 

 

uncorrectable memory error in DIMM s.

 

 

 

 

 

FLT

786s

DIMM

SBE&MBE DIMM s

Destructive memory test detected both an

 

 

 

 

uncorrectable and a correctable memory

 

 

 

 

error in DIMM s.

 

 

 

 

 

FLT

787s

DIMM

mem err DIMM s

Destructive memory test detected a

 

 

 

 

pattern compare error in DIMM s.

 

 

 

 

 

FLT

788s

DIMM

SBE in DIMM s

Destructive memory test detected a

 

 

 

 

correctable memory error in DIMM s.

 

 

 

 

 

FLT

7890

DIMM

MBE overwrt SBE

Firmware replaced a correctable memory

 

 

 

 

error entry in the PDT with an

 

 

 

 

uncorrectable memory error entry at the

 

 

 

 

same address.

 

 

 

 

 

FLT

7891

DIMM

dup entry in PDT

The PDT already contains an entry at

 

 

 

 

that address.

 

 

 

 

 

FLT

7892

SYS BD

PDT write error

Error adding the entry to the PDT.

 

 

 

 

 

FLT

7893

SYS BD

PDT is full

The PDT is full--cannot add new entry.

 

 

 

 

 

FLT

7900

SYS BD

no DMT entry

Internal error--cannot find DIMM entry.

 

 

 

 

 

FLT

7901

SYS BD

no rank entry

Internal error--cannot find rank entry.

 

 

 

 

 

FLT

7902

SYS BD

bad refrsh intvl

Computed refresh interval is invalid.

 

 

 

 

 

FLT

7903

SYS BD

mem intrlv fail

Cannot generate memory interleave.

 

 

 

 

 

FLT

7904

SYS BD

mem reloc failed

Cannot interleave with relocated range

 

 

 

 

(3.75GB - 4.0GB).

 

 

 

 

 

FLT

7905

SYS BD

mem intrlv error

Undefined memory interleave failure.

 

 

 

 

 

FLT

79FF

SYS BD

mem firmware err

Internal error--never expected this to

 

 

 

 

happen.

 

 

 

 

 

WRN

80F3

SYS BD

err rd IODC byte

Cannot read IODC from ROM or card.

 

 

 

 

 

WRN

80F4

EXT IO

boot read error

Cannot load IODC entry_init for boot

 

 

 

 

device.

 

 

 

 

 

WRN

80F5

EXT IO

boot exec error

Error initializing boot device.

 

 

 

 

 

WRN

80F6

EXT IO

boot read error

Cannot load IODC entry_io for boot

 

 

 

 

device.

 

 

 

 

 

66