HP unix manual Eeprom

Models: unix

1 204
Download 204 pages 13.99 Kb
Page 58
Image 58

Troubleshooting

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

Ostat

Code

FRU

Message

Description

 

 

 

 

 

TST

2n90

SYS BD

CPUn dcache ECC

CPU n is starting its data cache ECC

 

 

 

 

self-test.

 

 

 

 

 

FLT

2BAD

SYS BD

assertion fail

A firmware assertion failed.

 

 

 

 

 

TST

3n00

SYS BD

ROM checksum tst

Monarch CPU n is testing the boot ROM

 

 

 

 

integrity.

 

 

 

 

 

FLT

3n00

SYS BD

ROM checksum BAD

The boot ROM failed checksum.

 

 

 

 

 

INI

3n00

SYS BD

ROM checksum ok

The boot ROM passed checksum.

 

 

 

 

 

TST

3n01

SYS BD

PDH control test

Monarch CPU n is testing PDH control

 

 

 

 

register.

 

 

 

 

 

INI

3n01

SYS BD

PDH control init

Monarch CPU n is initializing the PDH

 

 

 

 

control register.

 

 

 

 

 

FLT

3n01

SYS BD

PDH control err

Monarch CPU n detected an error in the

 

 

 

 

PDH control register.

 

 

 

 

 

TST

3n02

SYS BD

scratch RAM test

Monarch CPU n is testing scratch RAM.

 

 

 

 

 

INI

3n02

SYS BD

scratch RAM ok

The scratch RAM test failed.

 

 

 

 

 

FLT

3n02

SYS BD

scratch RAM bad

The scratch RAM test passed.

 

 

 

 

 

WRN

3n03

SYS BD

stbl st read err

CPU n detected a non-fatal error reading

 

 

 

 

the stable store.

 

 

 

 

 

FLT

3n03

SYS BD

stbl st read err

CPU n detected a non-fatal error reading

 

 

 

 

the stable store.

 

 

 

 

 

INI

3nC4

SYS BD

clearing EEPROM

Monarch CPU n is clearing the EEPROM.

 

 

 

 

 

INI

3nD4

SYS BD

deflting EEPROM2

Monarch CPU n is initializing the

 

 

 

 

EEPROM to system defaults.

 

 

 

 

 

WRN

3n04

SYS BD

EEPROM write err

CPU n detected a non-fatal error writing

 

 

 

 

the EEPROM.

 

 

 

 

 

FLT

3n04

SYS BD

EEPROM write err

CPU n detected a fatal error writing the

 

 

 

 

EEPROM.

 

 

 

 

 

FLT

3n05

SYS BD

EEPROM wrt limit

CPU n detected a fatal error writing the

 

 

 

 

EEPROM.

 

 

 

 

 

WRN

3n06

SYS BD

EEPROM read err

CPU n detected a non-fatal error reading

 

 

 

 

the EEPROM.

 

 

 

 

 

FLT

3n06

SYS BD

EEPROM read err

CPU n detected a fatal error reading the

 

 

 

 

EEPROM.

 

 

 

 

 

INI

3n07

SYS BD

CPUn invoke LDB

CPU n is starting the low-level debugger.

 

 

 

 

 