Troubleshooting

 

 

 

 

Selftest Failures

Table 3-2. Chassis Codes for the B2000 Workstation

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

TST

4n60

SYS BD

CPUn dcache miss

CPU n is starting its data cache miss

 

 

 

 

self-test.

 

 

 

 

 

FLT

5n00

SYS BD

unknown bus err

CPU n detected an unknown error on the

 

 

 

 

system bus (Runway).

 

 

 

 

 

FLT

5n02

SYS BD

path err assertd

CPU n detected a path error on the

 

 

 

 

system bus (Runway).

 

 

 

 

 

FLT

5n04

SYS BD

parity error

CPU n detected a data, address, or control

 

 

 

 

parity error on the system bus (Runway).

 

 

 

 

 

FLT

5n07

SYS BD

Runway dir error

CPU n detected a directed error on the

 

 

 

 

system bus (Runway).

 

 

 

 

 

FLT

5n08

SYS BD

Runway broad err

CPU n detected a broadcast error on the

 

 

 

 

system bus (Runway).

 

 

 

 

 

FLT

5n0A

SYS BD

illegal response

CPU n received data that did not match

 

 

 

 

any outstanding data request.

 

 

 

 

 

FLT

5n0B

SYS BD

bus timeout

CPU n timed out before receiving

 

 

 

 

requested data. The responder is logged in

 

 

 

 

the system responder address.

 

 

 

 

 

FLT

5n0C

SYS BD

CPU sync failure

CPU n’s synchronizer detected a rule

 

 

 

 

violation on the system bus (Runway).

 

 

 

 

 

INI

7000

DIMM

start DIMM scan

Start looking for installed DIMMs.

 

 

 

 

 

INI

7002

SYS BD

init mem tables

Initialize memory data structures.

 

 

 

 

 

FLT

7004

SYS BD

mem plt upd fail

Error updating memory platform data.

 

 

 

 

 

FLT

7005

DIMM

insufficient mem

Insufficient memory detected to continue.

 

 

 

 

 

TST

7010

DIMM

check DIMM order

Start memory DIMM order check.

 

 

 

 

 

WRN

7011

DIMM

skip DIMM ord ck

Bypass memory DIMM order check.

 

 

 

 

 

FLT

7012

DIMM

DIMM order error

Memory DIMMs are not in the proper

 

 

 

 

order.

 

 

 

 

 

FLT

7013

DIMM

DIMM order error

Memory DIMMs are not in the proper

 

 

 

 

order. As a result, the system cannot

 

 

 

 

access one or more DIMMs and has

 

 

 

 

deallocated all inaccessible DIMMs.

 

 

 

 

 

TST

7016

DIMM

DIMM pair check

Start memory DIMM pair check (DIMMs

 

 

 

 

in a pair (e.g. 0a/0b) must match in

 

 

 

 

J7000).

 

 

 

 

 

WRN

7017

DIMM

skip mem pair ck

Bypass memory DIMM set check.

 

 

 

 

 

FLT

701F

DIMM

no memory found

Memory scan couldn’t find any DIMMs.

 

 

 

 

 

Chapter 3

61

Page 61
Image 61
HP unix manual CPU n is starting its data cache miss