Field Replaceable Units
FRU Removal and Replacement
Power Switch/LCD Assembly
This section explains how to remove and replace the power switch/LCD assembly, which is located on the front panel of the B2000 workstation.
Removing the Power Switch/LCD Assembly
Perform the following steps to remove the power switch/LCD assembly:
1.Open the workstation’s front panel as shown in the section “Opening the Front Panel.”
2.Unplug the power switch/LCD assembly’s connector as shown in Figure
Figure 4-4. Removing the Power Switch/LCD Assembly
Power Switch/LCD
Assembly Connector
Right Side
Mounting Clip
Power Switch/LCD
Assembly
Left Side
Mounting Clips
3.Press inward on the mounting clip located on the right side of the power switch/LCD assembly and pull the right side of the assembly outward in a clockwise motion. See Figure
Replacing the Power Switch/LCD Assembly
Perform the following steps to replace the power switch/LCD assembly:
1.Open the workstation’s front panel as shown in the section “Opening the Front Panel.”
2.Insert the mounting clips on the left side of the power switch/LCD assembly into the slots on the workstation chassis. See Figure
3.Press inward on the mount clip located on the right side of the power switch/LCD assembly and insert this clip into the hole provided for it on the workstation chassis.
4.Plug in the power switch/LCD assembly’s connector.
5.Close the workstation’s front panel as shown in the section “Closing the Front Panel.”
90 | Chapter 4 |