DSM250 User’s Manual

Figure 210 – Rectangular Tank Selection

The following screen will be displayed.

Figure 211 – Rectangular Tank Calibration

Enter the distance from the face of the TLM100 sensor to the bottom of the tank for the Empty Tank Depth, and the distance from the face of the TLM100 sensor to the top of the liquid when the tank is full for the Full Tank Depth.

After entering the values, use the Back button to return the parent menu.

6.24.5Tank Number

The Tank Number is the Data Instance used in the data message. This can be set from #0 to #15.

6.24.6Tank Type

This is set to the type of fluid in the tank. Values are:

Fuel

Fresh Water

Waste Water

Page 182

Revision 1.4.16a

Page 198