The choices that are offered are “Normal Installation” (default), “Backward Installation”,
6.22.4Label
This menu item allows you to set a text label for the device. This text label will help you to identify a particular device when you have more than one of the same type in the system, and appears when selecting devices in both the DSM250 and in N2KView.
See section 3.3.4 for details on how to enter a textual value.
6.22.5Magnetic Deviation Calibration
The DSM250 is capable of performing magnetic deviation calibration on a Maretron SSC200 solid state compass. The Rate of Turn Offset Calibration (section 6.22.8) should be done before the Deviation Calibration. The first screen (Figure 172) gives instructions for performing the procedure. First, begin to turn the boat in a slow circle (either clockwise or
Figure 172 – SSC200 Magnetic Deviation Calibration Start Screen
Once you have begun the turn, press Begin ( ) to start the calibration procedure. If you do not wish to perform magnetic deviation calibration at this time, press Abort ( ), and the currently stored deviation tables will be retained. If you are in a large vessel, it may be difficult to turn the vessel in a small enough circle to avoid significant centrifugal force applied to the compass during magnetic deviation calibration. This can cause the