DSM250 User’s Manual

The following sections explore each category in detail and spell out all of the data types that are available for display, if the appropriate sensors are installed in the network.

4.2.1 AC Bus

Average Frequency – displays average frequency of the AC power on the bus

Average L-N Voltage – displays average line to neutral RMS voltage of the AC power on the bus Average L-L Voltage – displays average line to line RMS voltage of the AC power on the bus Phase A Frequency – displays frequency of the AC power on phase A of the Bus

Phase A L-N Voltage – displays phase A Line-to-Neutral RMS voltage of the AC Bus Phase AB L-L Voltage – displays phase A Line-to-phase B Line RMS voltage of the AC Bus Phase B Frequency – displays frequency of the AC power on phase B of the bus

Phase B L-N Voltage – displays phase B Line-to-Neutral RMS voltage of the AC Bus Phase BC L-L Voltage – displays phase B Line-to-phase C Line RMS voltage of the AC Bus Phase C Frequency – displays frequency of the AC power on phase C of the bus

Phase C L-N Voltage – displays phase C Line-to-Neutral RMS voltage of the AC Bus Phase CA L-L Voltage – displays phase C Line-to-phase A Line RMS voltage of the AC Bus

4.2.2 AC Generator

Average Current – displays the average current of the AC power on the generator Average Frequency – displays the average frequency of the AC power on the generator Average L-N Voltage – displays average line to neutral RMS voltage of the AC power on the

generator

Average L-L Voltage – displays average line to line RMS voltage of the AC power on the generator

Total Real Power – displays real power output by the generator

Total Reactive Power – displays reactive power output by the generator Total Apparent Power – displays apparent power output by the generator Total Power Factor – displays power factor of the generator

Total kWH Export – displays total energy produced by the generator Total kWH Import – displays total energy consumed by the generator Phase A Current – displays phase A current of the Generator

Phase A Frequency – displays frequency of the AC power on phase A of the Generator Phase A L-N Voltage – displays phase A Line-to-Neutral RMS voltage of the Generator Phase AB L-L Voltage – displays phase A Line-to-phase B Line RMS voltage of the Generator Phase A Real Power – displays real power output on phase A of the generator

Phase A Reactive Power – displays reactive power output on phase A of the Generator Phase A Apparent Power – displays apparent power output on phase A of the Generator Phase A Power Factor – displays power factor of phase A of the Generator

Phase B Current – displays phase B current of the Generator

Phase B Frequency – displays frequency of the AC power on phase B of the Generator Phase B L-N Voltage – displays phase B Line-to-Neutral RMS voltage of the Generator Phase BC L-L Voltage – displays phase B Line-to-phase C Line RMS voltage of the Generator Phase B Real Power – displays real power output on phase B of the generator

Phase B Reactive Power – displays reactive power output on phase B of the Generator Phase B Apparent Power – displays apparent power output on phase B of the Generator Phase B Power Factor – displays power factor of phase B of the Generator

Phase C Current – displays phase C current of the Generator

Page 12

Revision 1.4.16a

Page 28
Image 28
Maretron DSM250-01 user manual AC Bus, AC Generator