DSM250 User’s Manual
Figure 215 – TMP100 Channel Configuration Screen
6.27.2.1Instance
The Data Instance of the Temperature (as sent in PGNs 130311, 130312, and 130823) is set in this field. Use the Increase and Decrease buttons to select the correct instance number, and the press the Enter button to store it.
6.27.2.2Source
In the NMEA2000® PGNs, each temperature is associated with a source type. Possible values are:
Bait Well Temperature
Engine Room Temperature
Exhaust Gas Temperature
Freezer Temperature
Heating System Temperature
Inside Temperature
Live Well Temperature
Main Cabin Temperature Outside Temperature Refrigeration Temperature Sea Temperature
User Defined Temperature #129...#144 – Use this when none of the above options are suitable.
Use the Scroll Up and Scroll Down buttons to select the correct source, and the press the Enter button to store it.
6.27.2.3Label
A label may be assigned to each channel of the TMP100 as an aid to identifying the temperature that is being displayed. Typically this label will describe the function or location of the temperature sensor.
6.27.3Device Label
A label may be assigned to the TMP100 as an aid to identifying the device over the network. Typically this label will describe the location of the TMP100.
Page 186 | Revision 1.4.16a |