Figure 228 – Installation Offset Abort Confirmation Screen
6.30.4Wind Data Damping Period
The WSO100 comes from the factory preset with a damping period of 1.5 seconds, which should be appropriate for most applications. However, you may use the DSM250 to tune the damping period to anywhere between 0.1 seconds and 5.0 seconds if you desire. To do this, use the Scroll Up ( ) or Scroll Down (
) keys to move the highlighted cursor to the “Wind Data Damping Period:” menu item, then press the Enter key (
) to move the highlight to the numerical value on the right. This is shown in Figure 229 below. Use the Increase and Decrease keys to adjust the damping period to the desired value, and then press the Enter key (
) to accept the value and store it within the WSO100.
Figure 229 – Setting the Wind Data Damping Period
6.30.5Barometric Pressure
The WSO100 has an internal barometer, which is
Revision 1.4.16a | Page 195 |