•Custom Calibration – use for
•Rectangular Tank – By inputting some dimensions of a rectangular tank, the FPM100 is able to interpolate the volume of liquid from the bottom of the tank to the surface.
Figure 103 – FPM100 Tank Levels Calibration Menu
6.13.2.1.6.1 Custom Calibration
The Custom Calibration setting will provide the most accurate tank level readings under any circumstances, but it requires that you go through a process in which you gradually fill the tank, stopping periodically to input the current fluid level. The TLA100 will measure the sender resistance at each point and create a custom calibration map which relates the resistance of the sender with the fluid levels. Figure 104 below shows a screenshot of the DSM250 with the Custom Calibration option highlighted. Custom calibration is necessary for
Figure 104 – Performing Custom Calibration of the Tank Level Adapter