DSM250 User’s Manual

6 Device Configuration

The “Device Configuration…” menu enables you to configure certain types of devices on the NMEA

2000® network. Devices that may be configured using the DSM250 include the following:

Airmar Depth, Speed, and Temperature Transducers (DST800, DT800, P39, P79, B122, ST850, ST800, HT200) – Reset trip log, set depth offset, speed calibration, and temperature offset (if applicable)

Bennett EP-30– Calibrate trim tabs.

Maretron Alternating Current Monitor (ACM100) – Set circuit type, device type, instance number, and label. Reset the total energy recorded.

Maretron Annunciator (ALM100) – Set the Data Instance Number, and the Label. Test the alarm.

Maretron Direct Current Monitor (DCM100) – Set the Battery Type, and calibrate the current sensor zero offset.

Maretron Direct Current Relay Module (DCR100) – Set the operating mode of each channel, lock switches, set power up state, and control state of switches

Maretron Monochrome Display (DSM200) – allows configuration of other DSM200s on the network

Maretron Color Display (DSM150,DSM250) – allows configuration of other DSM150s and DSM250s on network

Maretron Depth/Speed/Temp. Transducer (DST100) – set transducer offset, zero trip distance log

Maretron Depth/Speed/Temp. Transducer (DST110) – Reset trip log, set depth offset, speed calibration, and temperature offset

Maretron Engine Monitoring System (EMS100) – set the gauge types for Boost Pressure, Drive Trim, Oil Pressure and Water Temperature. Preset the Engine Hours

Maretron Fuel Flow Monitor (FFM100) – Set operating mode, channel direction, K-factor, temperature coefficient

Maretron Fluid Pressure Monitor (FPM100) – Set the operating mode of each channel, perform tank levels calibration, set pressure sender characteristics

Maretron GPS Antenna/Receiver (GPS100) – enable and disable WAAS functionality, set the GPS mode, program the elevation, PDOP and SNR masks, set the antenna altitude, force a cold start, enable/disable individual PGN transmission, and reset the unit back to its factory defaults.

Maretron GPS Antenna/Receiver (GPS200) – enable and disable WAAS functionality, force a cold start, enable/disable individual PGN transmission, and reset the unit back to its factory defaults.

Maretron Internet Protocol Gateway(IPG100) – set IP connection parameters, set N2KServer password, view N2KServer information, and reset the unit back to its factory defaults.

Maretron J1939 to NMEA 2000 Gateway (J2K100) – set J1939 node address, set NMEA 2000® engine/transmission instance, enable pass-through of J1939 diagnostic messages, and enable/disable individual NMEA 2000® PGN transmissions.

Maretron Network Bus Extender (NBE100) – Set device label

Maretron Rudder Angle Adapter (RAA100) – Set rudder number, operating mode, and calibrate rudder position.