6.21.3Instance
From here the instance used in the data message may be set.
6.21.4Channel Configuration
To configure an individual channel, use the Scroll Up and Scroll Down buttons to highlight the channel, and then press Enter. The following screen will be displayed.
Figure 163 – SIM100 Channel Configuration Screen
6.21.4.1Mode
To be able to detect broken connections, a SIM100 channel may be configured to detect an 8kΩ resistor at the end of the circuit in the open state. In this case a fully open circuit will reported as a fault condition. See the manual for details.
Valid Modes are:
Disable – the channel is not being used
End Of Line Resistor – an open circuit is a fault condition.
No End Of Line Resistor – an open circuit is not a fault condition.
Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key.
6.21.4.2Label
A label may be assigned to a channel as an aid to identifying the channel over the network. Typically this label will describe the function of the switch connected to the channel.
See section 3.3.4 for details on how to enter a textual value.