®
Figure 191 – Custom Tank Level Calibration Confirmation Screen
6.23.4.2American Standard Sender Calibration
If you have a rectangular tank, and a sender with the standard American resistance range (240 ohms full, 33 ohms empty), and you know the capacity of the tank, you can easily calibrate the sender by using the “Set to American Standard
Figure 192 – American Standard Sender Calibration
6.23.4.3European Standard Sender Calibration
If you have a rectangular tank, and a sender with the standard European resistance range (0 ohms full, 180 ohms empty), and you know the capacity of the tank, you can easily calibrate the sender by using the “Set to European Standard
Revision 1.4.16a | Page 171 |