DSM250 User’s Manual
•
•Type – you may choose between the default value of “Toggle”, in which case the switch/breaker changes state every time you press the power button while it is highlighted, or “Momentary”, in which case the
•Instance – the instance number of the switch bank containing the switch/breaker to be controlled.
•Channel – the channel number of the switch/breaker to be controlled.
•Title – Sets the text string to be displayed on the switch/breaker. Please refer to Section Error! Reference source not found. for details.
•Font Size – Sets the size of the font used to display the label on the switch/breaker. You may select Small, Medium, or Large (default).
•Restore Factory Defaults – This restores the switch/breaker to factory default settings.
In order to control a switch/breaker using the DSM250, create a screen with a switch/breaker which has been configured to refer to the switch bank instance and indicator number of the switch/breaker you want to control.
In normal operating mode, use the “Scroll Up” and “Scroll Down” keys to change to the screen containing the switch/breaker. Once that screen is displayed, follow these steps to change a load’s state:
1.Press the “Enter” key for approximately one second. This will place the display into “Control mode”, and one of the switches/breakers on the screen will be highlighted with a thick border, as shown in Figure 252 below.
2.If there is more than one switch/breaker on the screen, you may use the “Scroll Up” and “Scroll Down” keys to change the highlight to a different switch/breaker.
3.Once the switch/breaker for the load you want to control is selected, then press the “Power” key. The load referenced by the switch/breaker will be commanded to change state, and the changed state will be reflected in the switch/breaker.
4.To change other loads, repeat the process.
5.To stop controlling loads, press the “Lights” key to return to normal operating mode. The highlight will disappear.
Page 210 | Revision 1.4.16a |