6.11.7Drive Trim Sender Offset
Often, the characteristics of individual drive trim senders vary from their specified values. This setting allows you to apply an offset to the resistance value of the drive trim sender in order to allow you to bring the digital value reported by the EMS100 into agreement with that displayed by the analog gauge. Valid options are:
•
Select the required option using the Increase and Decrease keys followed by the Enter key.
6.11.8Oil Pressure Gauge Type
The EMS100 comes from the factory preprogrammed with the characteristics of oil pressure gauge types for supported engines. If the EMS100 is used with an analog oil pressure gauge, you must select the correct type of gauge for this setting in order for the data to be displayed correctly. Valid options are:
•No Gauge – select this option if there is no oil pressure gauge present.
•YANMAR
•YANMAR W/THRESHOLD
•YANMAR / VDO
•YANMAR/VDO W/THRESHOLD
Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key.
6.11.9Oil Pressure Sender Type
The EMS100 comes from the factory preprogrammed with the characteristics of oil pressure senders for supported engines. If the engine to which you are connecting the EMS100 has a oil pressure sender, you must select the correct type of oil pressure sender for this setting in order for the data to be displayed correctly. Valid options are:
•Disabled – select this option if there is no oil pressure sender present.
•YANMAR
•YANMAR / VDO
Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key.
6.11.10Oil Pressure Sender Offset
Often, the characteristics of individual oil pressure senders vary from their specified values. This setting allows you to apply an offset to the resistance value of the oil pressure sender in order to allow you to bring the digital value reported by the EMS100 into agreement with that displayed by the analog gauge. Valid options are:
•
Select the required option using the Increase and Decrease keys followed by the Enter key.
Revision 1.4.16a | Page 93 |