Introduction

Model GFC7000TA Carbon Dioxide Analyzer

1. INTRODUCTION

The Models GFC 7000TA and GFC 7000TM differ only in specifications; unless clearly differentiated, both models in this manual are referred to as the GFC 7000TA for simplification. The GFC 7000TA measures carbon dioxide CO2 by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law. This is accomplished by using a Gas Filter Wheel which alternately allows a high energy infrared light source to pass through a CO2 filled chamber and a chamber with no CO2 present.

The light then travels through the sample cell, which has a folded path. The energy loss through the sample cell is compared with the zero reference signal provided by the gas filter to produce an output proportional to concentration, with little effect from interfering gases within the sample. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.

This design produces superior zero and span stability and a high signal-to-noise ratio, allowing excellent sensitivity. Multi-tasking software gives real time indication of numerous operating parameters and provides automatic alarms if diagnostic limits are exceeded

1.1. Features

Ranges, GFC 7000TA: 0-2 ppm to 0-2000 ppm, GFC 7000TM: 0-4 ppm to 0-4000 ppm, user selectable

Gas Filter Wheel for CO2 specific measurement

LCD Graphical User Interface with capacitive touch screen

Multi-tasking software allows viewing of test variables during operation

Continuous self checking with alarms

Bi-directional RS-232 and 10/100Base-T Ethernet (optional USB and RS-485) ports for remote operation

Front panel USB ports for peripheral devices

Digital status outputs to indicate instrument operating condition

Adaptive signal filtering to optimize response time

Temperature & Pressure compensation

Internal data logging with 1 min to 24 hour averages

1.2. Using This Manual

This manual has the following data structures:

1 TABLE OF CONTENTS:

Outlines the contents of the manual in the order the information is presented. This is a good overview of the topics covered in the manual. There is also a list of tables, a list of figures and a list of appendices.

2 SPECIFICATIONS

This section contains a list of the analyzer’s performance specifications.

Teledyne Analytical Instruments