The pin assignments for the Status Outputs are:

Table 6-24: Status Output Pin Assignments

OUTPUT #

Status Definition

Condition

 

 

 

1

SYSTEM OK

On if no faults are present.

2

CONC VALID

On if CO2 concentration measurement is valid.

 

If the CO2 concentration measurement is invalid, this bit is OFF.

 

 

3HIGH RANGE On if unit is in high range of DUAL or AUTO range modes.

4ZERO CAL On whenever the instruments zero point is being calibrated.

5SPAN CAL On whenever the instruments span point is being calibrated.

6DIAG MODE On whenever the instrument is in diagnostic mode.

7

ALARM1

On whenever the measured CO2 concentration is above the set point for

ALM1

 

 

 

8

ALARM2

On whenever the measured CO2 concentration is above the set point for

ALM2

 

 

 

D

EMITTER BUS

The emitters of the transistors on pins 1-8 are bused together.

+

DC POWER

+ 5 VDC

 

 

Digital Ground

The ground level from the analyzer’s internal DC power supplies.

 

 

 

 