Chapter 7 NPE-G1 and NPE-G2 Installation and Configuration Information

Installing the NPE-G1 or NPE-G2

Figure 7-24 Connecting AC-Input Power to a Cisco 7200 VXR Router

1

84398

2

3

4

5

1

Power switch

4

Cable-retention clip

 

 

 

 

2

AC power cable

5

Hole for nylon cable tie

 

 

 

 

3

POWER OK LED

 

 

 

 

 

 

Step 4 Plug the AC power supply cable into the AC power source.

Note For Cisco 7200 VXR routers, each AC-input power supply operating at 120 VAC requires a minimum of 5A service.

We recommend powering the Cisco 7200 VXR routers from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power source.

Step 5 Repeat Step 1 through Step 4 if a second power supply is installed.

This completes the steps for reconnecting AC-input power to a Cisco 7200 VXR router. Proceed to the “Powering Up the Router” section on page 7-45.

Network Processing Engine and Network Services Engine Installation and Configuration

7-36

OL-4448-12

 

 