Chapter 6 SPA9000 Field Reference

Regional Tab

Control Timer Values (sec)

Field

Description

 

 

Hook Flash Timer Min

Minimum on-hook time before off-hook qualifies as hook-flash. Less than this the

 

on-hook event is ignored. Range: 0.1–0.4 seconds.

 

The default is 0.1.

 

 

Hook Flash Timer Max

Maximum on-hook time before off-hook qualifies as hook-flash. More than this the

 

on-hook event is treated as on-hook (no hook-flash event). Range: 0.4–1.6 seconds.

 

The default is 0.9.

 

 

Callee On Hook Delay

Phone must be on-hook for at this time in sec before the SPA9000 will tear down the

 

current inbound call. It does not apply to outbound calls. Range: 0–255 seconds.

 

The default is 0.

 

 

Reorder Delay

Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf =

 

never plays. Range: 0–255 seconds.

 

The default is 5.

 

 

Call Back Expires

Expiration time in seconds of a call back activation. Range: 0–65535 seconds.

 

The default is 1800.

 

 

Call Back Retry Intvl

Call back retry interval in seconds. Range: 0–255 seconds.

 

The default is 30.

 

 

Call Back Delay

Delay after receiving the first SIP 18x response before declaring the remote end is

 

ringing. If a busy response is received during this time, the SPA9000 still considers the

 

call as failed and keeps on retrying.

 

The default is 0.5.

 

 

VMWI Refresh Intvl

Interval between VMWI refresh to the CPE.

 

The default is 0.5.

 

 

Interdigit Long Timer

Long timeout between entering digits when dialing. The interdigit timer values are used

 

as defaults when dialing. The Interdigit_Long_Timer is used after any one digit, if all

 

valid matching sequences in the dial plan are incomplete as dialed. Range: 0–64 seconds.

 

The default is 10.

 

 

Interdigit Short Timer

Short timeout between entering digits when dialing. The Interdigit_Short_Timer is used

 

after any one digit, if at least one matching sequence is complete as dialed, but more

 

dialed digits would match other as yet incomplete sequences. Range: 0–64 seconds.

 

The default is 3.

 

 

 