Appendix
Buttons
Pos. Button | Function |
This button is used to switch the server on or off.
IIf the system is running an
2 | On / Off button | button will performs a graceful shutdown. |
Pressing and holding the On / Off button for five seconds will switches the server off without shutting down the operating system.
15.4Minimum startup configuration
Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to take the system down to its most basic configuration in order to isolate the defective component.
The minimum startup configuration consists of the following components and cables:
Component | Notes |
System board | no TPM or expansion cards installed |
|
|
CPU with CPU heat sink |
|
|
|
1 memory module | installed in slot 1 |
|
|
PSU |
|
|
|
Table 7: Minimum startup configuration - components |
Cable | Notes and reference | |
Front panel cable |
| |
|
| |
Power cable | see section "Replacing the power cable" on | |
page 239 | ||
| ||
Table 8: Minimum startup configuration - cables |